        公務員期刊網(wǎng) 精選范文 電線電纜試驗報告范文

        電線電纜試驗報告精選(九篇)

        前言:一篇好文章的誕生,需要你不斷地搜集資料、整理思路,本站小編為你收集了豐富的電線電纜試驗報告主題范文,僅供參考,歡迎閱讀并收藏。

        電線電纜試驗報告

        第1篇:電線電纜試驗報告范文

        關(guān)鍵詞:準備工作 試驗接線 試驗方法 注意事項 試驗分析

        中圖分類號:TM247 文獻標識碼:A 文章編號:1672-3791(2016)03(b)-0034-02

        當電纜的絕緣中存在部分受潮,全部受潮或留有擊穿痕跡時,絕緣電阻的變化取決于這些缺陷是否貫穿于兩極之間。如缺陷貫穿兩極之間,絕緣電阻會有靈敏的反映。如只發(fā)生局部缺陷,電極間仍保持著良好絕緣,絕緣電阻將很少降低,甚至不發(fā)生變化。因此,絕緣電阻只能有效地檢測出整體受潮和貫通性的缺陷。

        1 測試前的準備工作

        (1)了解被試設(shè)備現(xiàn)場情況及試驗條件。

        (2)試驗儀器、設(shè)備準備。

        (3)辦理工作票并做好試驗現(xiàn)場安全和技術(shù)措施。

        2 現(xiàn)場試驗步驟要求及注意事項

        2.1 三相電纜芯線對地及相間絕緣電阻試驗

        (1)試驗接線。試驗應分別在每一相上進行,對一相進行試驗時,其他兩相芯線、金屬屏蔽或金屬護套(鎧裝層)接地。試驗接線如圖1所示

        (2)操作步驟。

        ①拉開電纜兩端的線路和接地刀閘,將電纜與其他設(shè)備連接完全斷開,對電纜進行充分放電,對端三相電纜懸空。檢驗絕緣電阻表完好后,將測量線一端接絕緣電阻表“L”端,另一端接絕緣桿,絕緣電阻表“E”端接地。

        ②通知對端試驗人員準備開始試驗,試驗人員驅(qū)動絕緣電阻表,用絕緣桿將測量線與電纜被試相搭接,待絕緣電阻表指針穩(wěn)定后讀取I min絕緣電阻值并記錄。試驗完畢后,用絕緣桿將連接線與電纜被試相脫離,再關(guān)停絕緣電阻表,對被試相電纜進行充分放電。

        按上述步驟進行其他兩相絕緣電阻試驗。

        2.2 電纜外護套絕緣電阻試驗

        (1)試驗接線。電纜外護套(絕緣護套)的絕緣電阻試驗接線如圖2所示。

        (2)操作步驟:測量外護套的對地絕緣電阻時,將“金屬護層”、“金屬屏蔽層”接地解開。將測試線一端接絕緣電阻表“L”端,另一端接絕緣桿,絕緣電阻表“E”端接地。檢驗絕緣電阻表完好后,驅(qū)動絕緣電阻表,將絕緣桿搭接“金屬護層”,讀取Imin絕緣電阻值并記錄。測試完畢后,將絕緣桿脫離“金屬護層”,再停止絕緣電阻表,并對“金屬護層”進行放電。試驗完畢后,恢復金屬護層、金屬屏蔽層接地。

        2.3 試驗注意事項

        (1)在測量電纜線路絕緣電阻時,必須進行感應電壓測量。

        (2)當電纜線路感應電壓超過絕緣電阻表輸出電壓時,應選用輸出電壓等級更高的絕緣電阻表。

        (3)在測量過程必須保證通信暢通,對側(cè)配合的試驗人員必須聽從試驗負責人指揮。

        (4)絕緣電阻測試過程應有明顯充電現(xiàn)象。

        (5)電纜電容量大,充電時間較長,試驗時必須給予足夠的充電時間,待絕緣電阻表指針完全穩(wěn)定后方可讀數(shù)。

        (6)電纜兩端都與GIS相連,在試驗時若連接有電磁式電壓一甌感器,則應將電壓互感器的一次繞組末端接地解開,恢復時必須檢查。

        3 測試結(jié)果分析及報告編寫

        3.1 測試結(jié)果分析

        (1)測試標準及要求。根據(jù)《電氣裝置安裝E程電氣設(shè)備交接試驗標準》 (GB 50150-2006)規(guī)定。

        ①電纜線路絕緣電阻應在進行交流或直流耐壓前后分別進行測量,耐壓試驗前后絕緣電阻測量值應無明顯變化。

        ②橡塑電纜外護套、內(nèi)襯套的絕緣電阻不低于0.5 MΩ/km。

        (2)測試結(jié)果分析。

        ①直埋橡塑電纜的外護套,特別是聚氯乙烯外護套,受地下水的長期浸泡吸水后,或者受到外力破壞而又未完全破損時,其絕緣電阻均有可能下降至規(guī)定值以下。

        ②35 kV及以下電壓等級的三相電纜(雙護層)外護套破損不一定要立即修理,但內(nèi)襯層破損進水后,水分直接與電纜芯接觸,并可能腐蝕銅屏蔽層,一般應盡快檢修。35 kV及以上電壓等級的單相或三相電纜(單護層)外護套破損一定要立即修復,以免造成金屬護層多點接地,形成環(huán)流。

        ③由于電纜電容量大,在絕緣電阻測試過程如測量時間過短,“充電”還未完成就讀數(shù),易引起對試驗結(jié)果的誤判斷。

        ④測得的芯線及護層絕緣電阻都應達到上述規(guī)定值,在測量過程中還應注意是否有明顯的充電過程,以及試驗完畢后的放電是否明顯。若無明顯充電及放電現(xiàn)象,而絕緣電阻值卻正常,則應懷疑被試品未接入試驗回路。

        3.2 試驗報告編寫

        試驗報告編寫應包括以下項目:被試電纜運行編號、試驗時間、試驗人員、天氣情況、環(huán)境溫度、濕度、被試電纜參數(shù)、運行編號、使用地點、試驗結(jié)果、試驗結(jié)論、試驗性質(zhì)(交接、預防性試驗、檢查、實行狀態(tài)檢修的應填明例行試驗或診斷試驗)、試驗裝置名稱、型號、出廠編號,備注欄寫明其他需要注意的內(nèi)容,如是否拆除引線等。

        4 電纜試驗操作危險點分析及控制措施

        (1)掛接地線時,應使用合格的驗電器驗電,確認無電后再掛接地線。嚴禁使用不合格驗電器驗電,禁止不戴絕緣手套強行盲目掛接地線。

        (2)接地線截面、接地棒絕緣電阻應符合被測電纜電壓等級要求;裝設(shè)接地線時,應先接接地端,后接導線端:接地線連接可靠,不準纏繞;拆接地線時的程序與此相反。

        (3)連接試驗引線時,應做好防風措施,保證足夠的安全距離,防止其漂浮到帶電側(cè)。

        (4)電纜及避雷器試驗前非試驗相要可靠接地,避免感應觸電。

        (5)所有移動電氣設(shè)備外殼必須可靠接地,認真檢查施工電源,防止漏電傷人,按設(shè)備額定電壓正確裝設(shè)漏電保護器。

        (6)電氣試驗設(shè)備應輕搬輕放,往桿、塔上傳遞物件時,禁止拋遞拋接。

        (7)桿、塔上試驗使用斗臂車拆搭火時,現(xiàn)場應設(shè)監(jiān)護人,斗臂車起重臂下嚴禁站人,服從統(tǒng)一指揮,保IIE與帶電設(shè)備保持安傘距離。

        (8)桿、塔上工作必須穿絕緣鞋、戴安全帽(安全帽系帶)、系腰繩。

        (9)認真核對現(xiàn)場停電設(shè)備與工作范圍。

        (10)被試電纜與架空線連接斷開后,應將架空引下線固定綁牢,防止隨風飄動,并保證試驗安全距離。

        參考文獻

        [1] 崔祥柱.電線電纜絕緣電阻試驗[J].裝備制造,2009(11):143.

        第2篇:電線電纜試驗報告范文

        數(shù)千米長的電纜線路具有大電容,例如10km長的110kV交聯(lián)聚乙烯(XLPE)絕緣電纜,按其截面積的不同,電容可達2~3μF。如果在系統(tǒng)的頻率(50Hz)下用交流電壓進行現(xiàn)場試驗,就需要很大的無功功率。如上所述的電纜,在160kV(2.5u0)下進行交流電壓試驗,則可能需要高達20MVA的試驗功率。常規(guī)的交流電壓試驗設(shè)備(運行頻率50Hz)的缺點在于其單位試驗功率的重量較大,達100~200N/kVA,試驗設(shè)備的運輸很不經(jīng)濟,而且需要在現(xiàn)場提供相當大的電源。

        眾所周知,油浸紙絕緣電力電纜的現(xiàn)場試驗一般都采用直流電壓。試驗時可以同時測量泄漏電流,由泄漏電流的變化或者泄漏電流與試驗電壓的關(guān)系,可用以判斷絕緣狀況。數(shù)十年對油浸紙絕緣電力電纜采用直流耐壓試驗的實踐,已證明其作為現(xiàn)場定期預防性試驗項目能得出滿意的試驗結(jié)果,這也就是充油和壓氣電纜用直流電壓進行現(xiàn)場試驗的理由。這個試驗方法也同樣用于高壓XLPE絕緣電纜,它似乎是唯一可行的方法。

        1XLPE絕緣電纜線路用直流耐壓試驗的缺點

        高壓XLPE電纜線路的運行試驗表明,現(xiàn)場采用直流耐壓試驗不能有效地檢出有缺陷的XLPE絕緣電纜及附件。各國運行經(jīng)驗發(fā)現(xiàn)通過直流耐壓試驗的XLPE絕緣電纜及附件在投入運行后有擊穿故障發(fā)生。

        為此,CIGREWG21-09工作組(高壓擠包絕緣電纜試驗)于1984年向世界各國電纜制造商和電力公司調(diào)查,并組織進行模擬結(jié)構(gòu)樣品試驗,進一步確認高壓XLPE絕緣電纜采用直流耐壓試驗是不恰當?shù)?,其存在以下明顯的缺點:

        a)直流電壓下絕緣電場分布與交流電壓下電場分布不同,前者按電阻率分布,而后者按介電系數(shù)分布,尤其在電纜終端和接頭等高壓電纜附件中,直流電場強度的分布與交流電場強度分布完全不同。這往往造成交流工作電壓下有缺陷部位在直流耐壓的現(xiàn)場試驗時不會擊穿而被檢出,或者在交流工作電壓下絕不會產(chǎn)生問題的部位,而在直流耐壓現(xiàn)場試驗時發(fā)生擊穿。

        b)XLPE自身的固有場強高,要用很高的直流試驗電壓甚至嚴重損傷電纜才能檢出。例如,20kVXLPE電纜絕緣的50%處有金屬尖端,結(jié)果卻在10U0的直流電壓下才能使其擊穿。再者,在接頭內(nèi)有金屬尖端或密封電纜頭周圍有嚴重的缺陷,即使用12U0~16U0直流電壓試驗也不可能檢出。

        c)由于XLPE的高絕緣電阻和相應的空間電荷效應,尚不能排除在直流電壓下會造成XLPE電纜絕緣非故意的預先損傷。直流耐壓試驗時形成的空間電荷,可造成電纜在投入交流工作電壓運行時擊穿,或附件界面因積聚電荷而沿界面滑閃。

        2調(diào)頻串聯(lián)諧振裝置實例

        傳統(tǒng)的直流電壓試驗存在著嚴重缺點,必須尋求新的較為有效的試驗方法。非常自然的、符合絕緣機理的傾向,是采用交流電壓試驗方法,關(guān)鍵是要開發(fā)新型的交流電壓試驗設(shè)備。本文將詳細介紹由西門子柏林電力電纜廠等研制的8MVA,160kV調(diào)頻串聯(lián)諧振試驗裝置。

        2.1移動式

        調(diào)頻串聯(lián)諧振裝置設(shè)計的首要目的是試驗安全、簡便和快速,整個試驗設(shè)備均安裝在低底架的大卡車上。最重的組件是電抗器,重156.8kN。車輛總重量約400kN。

        2.2試驗電壓連接線

        電源電壓經(jīng)OHL門架的戶外終端和變壓器的輸出端或氣體絕緣開關(guān)(GIS)而饋電至用戶的電纜線路。通常連接到試驗設(shè)備的電抗器,包括可接至戶外套管或試驗電纜的插入式澆注樹脂絕緣管。內(nèi)部絕緣為SF6,以便能夠快速、安全和干燥地裝配。

        1—帶有固定電感的電抗器,并可改變電壓輸出;2—戶外終端;3—已裝在電纜盤上的試驗電纜,帶有符合IEC859的開關(guān)設(shè)備的密封終端;4—饋電連接電纜;5—SF6氣體充氣站;6—用液壓驅(qū)動的起吊機;7—控制室;8—戶外終端運輸用的貯存器

        2.3戶外套管

        戶外套管的戶外部分有防水硅橡膠裙邊,并模鑄在耐壓的增強玻璃纖維塑料支撐管上。戶外套管的內(nèi)部,導體是用交聯(lián)聚乙烯絕緣并用硅橡膠電容式應力錐來控制場強。附加的內(nèi)部絕緣為SF6。這種結(jié)構(gòu)使安裝比較容易,此外,試驗也不會受天氣的影響。

        戶外套管裝在電抗器上,用柔軟的銅導線接至被試電纜線路的戶外密封終端。如果該銅導線很長或沿著曲折的途徑,則應采用絕緣子來支撐。

        2.4GIS饋電的試驗電纜

        如果被試電纜和系統(tǒng)端接在GIS(氣體絕緣開關(guān)設(shè)備)內(nèi),則電源饋電線可接至為試驗而特殊安裝的連接器殼體,殼體尺寸符合IEC859要求。

        兩端都有密封終端的試驗電纜繞在電纜盤(安裝在車上)上,而且可拉開至70m長。用電子器件控制電纜盤的傳動機構(gòu)使敷設(shè)試驗電纜時達到靈活而且支撐牢固。用試驗電纜可接至現(xiàn)場GIS附近的任何地方。

        試驗電纜的密封終端,與戶外套管一樣都是充以SF6氣體,確保裝配工作簡易和安全。

        2.5初級電源的連接電纜

        在大多數(shù)使用場合,試驗電源均從用戶的系統(tǒng)獲取。根據(jù)被試電纜的長度和電容,視在功率可能需要達200kVA。但是,在很多的試驗場合下,可能僅僅需要電源視在功率小于50kVA。為此,運輸車還有裝在電纜盤上的連接電纜,長度200m。

        在所接入的電源負荷較大的場合或者饋電位置遠離公用電源系統(tǒng)時,本移動式大容量調(diào)頻串聯(lián)諧振裝置還添加有可靈活移動的發(fā)電機。

        2.6絕緣氣體源的環(huán)境安全

        運輸車上有SF6氣體充氣站,提供所需的SF6氣體以及充氣至密封終端的真空和壓力系統(tǒng),并提供可排氣和再充氣5MPa的壓力容器。

        2.7在運輸車上起吊工作

        戶外終端或試驗電纜密封終端安裝至電抗器需要質(zhì)量達100kg的起重機。起重機也安裝在拖車上。這樣,在用戶的現(xiàn)場就可直接進行工作而不受其他任何輔助設(shè)備的限制。

        在開始安裝的時候,通常不可能與用戶的電網(wǎng)相連接。因此,起重機由直流電動機液壓驅(qū)動,直流電動機由拖車上的蓄電池供電。這樣,進行試驗的準備工作不會有任何延誤。

        2.8設(shè)備控制和用戶操作室

        運輸車是按成套移動式調(diào)頻串聯(lián)裝置而設(shè)計的,適用于戶外使用。因此,也裝有寬敞的測試間。其內(nèi)包括電子器件控制設(shè)備,計算機控制的聯(lián)機裝置以及容納操作和觀察人員的足夠空間。用戶能在各種氣候條件下從事試驗,而且便于試驗時做記錄或試驗全部結(jié)束后立即編寫試驗報告。

        3運行經(jīng)驗

        本試驗裝置自研制成功后,已用于110kVXLPE絕緣電纜線路的現(xiàn)場試驗,并取得初步有效運行經(jīng)驗。

        自從1996年以來,已在高壓電纜線路進行交流電壓試驗。大約80%的試驗連接是經(jīng)由戶外密封終端而進行的,約20%則是經(jīng)由GIS開關(guān)裝置進行。在已試驗的電纜線路中,長度最長的約3.8km,最高試驗電壓為160kV,僅利用試驗設(shè)備最大功率的50%。這意味著還可以試驗更長的電纜線路。

        經(jīng)由戶外密封終端可方便地把交流電壓饋電至被試電纜線路。接線方式如圖2所示。利用銅導線把電抗器的電壓輸出接至電纜密封終端。

        4結(jié)束語

        用于長距離電纜線路的交流電壓試驗,需要相當大和重的試驗設(shè)備。為此,以往的XLPE電纜都是采用直流電壓試驗。高壓XLPE電纜線路的運行經(jīng)驗表明,采用直流電壓耐壓試驗不能有效地檢出XLPE電纜缺陷,特別是有缺損的XLPE電纜附件。這一點已取得國際共識,采用更有效的試驗方法勢在必行。

        通過對工頻串聯(lián)諧振試驗裝置的研究和試制,已獲得一種適合于XLPE絕緣電纜和附件的試驗方法,即施加工頻或接近工頻的交流電壓,在電纜及附件上產(chǎn)生的電場分布與實際運行工作電壓下的電場分布相同,能夠比較有效地檢出XLPE電纜及附件缺陷,并逐步成為各國用作XLPE絕緣電纜線路的現(xiàn)場試驗方法。

        本文所介紹的新型調(diào)頻串聯(lián)諧振試驗裝置,是把供電電源、產(chǎn)生試驗能量的主設(shè)備、連接至電纜線路的專用連接線和控制單元等所有組件全部安裝在低底架的拖車上。這樣就能機動靈活便于運作。迄今,最頻繁使用的是把試驗電壓接至戶外密封終端,也進行過把交流電壓經(jīng)由試驗電纜而饋電至符合IEC859的GIS開關(guān)設(shè)備。運行經(jīng)驗表明,該裝置的電氣系統(tǒng)和連接技術(shù)兩者的研制都是令人滿意的,而且可對高壓XLPE絕緣電纜線路進行既可靠又經(jīng)濟的交流電壓試驗。

        綜上所述,開發(fā)并應用適合現(xiàn)場試驗的交流高壓試驗裝置具有現(xiàn)實意義。我們要借助國外的經(jīng)驗,加強試驗設(shè)備研制開發(fā),加強試驗技術(shù)的研究,希望高壓XLPE絕緣電纜線路的現(xiàn)場試驗會有突破性成就。

        參考文獻

        1WeinbergW,GoehlichL,ScharchmidtJ.SitetestsofXLPE-insulatedhigh-voltagecablesystemswithACvoltage[J].ElektrizittsWirtschaft,1997,96(9):400~407

        第3篇:電線電纜試驗報告范文

        關(guān)鍵詞: 建筑電氣;施工質(zhì)量管理;準備;安全管理

        Abstract: Building electrical engineering construction is an important branch of engineering; electrical engineering quality directly affects the quality of the whole project. Building electrical engineering quality control should be in the whole process, all-around. In recent years, along with electrical equipment and the continuous development of species increases, electrical installation technology is more complex. For a building electrical engineering project, from start to completion, the construction site management from first to last plays an important role.

        Key words: electrical construction; construction quality management; preparation; safety management

        中圖分類號:TU71文獻標識碼:A 文章編號:

        隨著建筑電氣智能化技術(shù)的迅速發(fā)展,房地產(chǎn)業(yè)這一國民經(jīng)濟的支柱行業(yè),也如雨后春筍般迅猛發(fā)展,但同時,各種各樣的建筑質(zhì)量問題,尤其是建筑電氣的質(zhì)量問題也頻頻發(fā)生。在整個建筑工程項目中建筑電氣工程雖然不是主體工程,但在建設(shè)工程中的復雜程度和投資比重卻越來越大。為了提高房屋建設(shè)的總體質(zhì)量,就必須保證建筑電氣工程的施工質(zhì)量。建筑電氣工程,對于一個建設(shè)工程的使用功能、竣工后運行的安全可靠程度、投資效益的體現(xiàn)等,都有著舉足輕重的地位?,F(xiàn)結(jié)合實際工作,有針對性地對加強建筑電氣工程的施工管理問題進行了探討。

        一、建筑電氣施工前的準備工作

        1、做好電氣設(shè)計委托書

        設(shè)計委托書應包括電氣要求篇章,如果設(shè)計委托書不能詳盡地有效地表達出建設(shè)單位對擬建工程的各項電氣使用的具體要求,設(shè)計單位完成的施工圖將是不完整的。委托書應明確施工圖設(shè)計對電氣的要求、功能,應包括各項技術(shù)指標,主要設(shè)備的情況和建設(shè)位置提供電源的位置方式,各相關(guān)專業(yè)與其他建筑物電氣連接的要求和條件以及使用性質(zhì),并包括工作制和工作時間,決定供配電設(shè)計的級別及設(shè)備用電計算利用系數(shù)等。

        2、把好審圖關(guān)

        設(shè)計單位提交設(shè)計圖紙后,建設(shè)單位電氣部門主管人員應審核電氣設(shè)計指標、設(shè)備布置、強電、弱電電路布線等。第一階段的審圖應著眼于總體性、方案性等重大原則問題。如這一關(guān)不能嚴格把住必將造成一邊建設(shè)一邊修改或建成后馬上改,造成浪費。在完成第一階段的審圖后,第二階段的審圖即為技術(shù)交底和開工前的準備,設(shè)計單位向施工單位做一次較全面的圖紙說明。

        3、做好設(shè)備選型。

        一般情況下工藝設(shè)備由使用單位提供,保障系統(tǒng)由建設(shè)單位按圖紙要求定貨,嚴格控制質(zhì)量,嚴格選擇供貨單位。現(xiàn)代建筑燈具不只有照明作用,其裝飾性、藝術(shù)性在建筑物內(nèi)起著重要作用,燈具選擇要特別注意其電氣性能指標。工程材料、器件和設(shè)備質(zhì)量,是保證工程質(zhì)量的先天因素,電氣管理人員須認識電氣設(shè)備和材料的種類、型號、規(guī)格的不同,性能和標準也有所不同。必須對設(shè)備材料嚴格按質(zhì)量標準和設(shè)計要求進行訂貨、采購、運輸和保管,這其中某個環(huán)節(jié)處理不當都將會影響工程質(zhì)量。同時還要核實材料和設(shè)備的合格證、說明書裝配圖和試驗報告等有關(guān)資料。做到不合格的設(shè)備和材料不采購、不驗收、不使用。對進場的合格材料和設(shè)備要及時填寫“工程材料報驗單”,并附材料清單,材質(zhì)證明(檢驗報告),經(jīng)檢驗,認定合格后,方允許用于工程,并妥善保管,防止受潮、發(fā)霉、損壞。在具體安裝過程中,對于電氣材料的各種電氣性能試驗(如交流耐壓、直流耐壓、泄漏電流試驗、絕緣電阻測定、接地電阻測定等)均應按規(guī)范要求進行。

        二、建筑電氣施工階段的質(zhì)量控制

        施工中必須根據(jù)已會審后的電氣施工圖紙和有關(guān)技術(shù)文件,按照國家現(xiàn)行的電氣工程施工及驗收規(guī)范,地方有關(guān)工程建設(shè)的法規(guī)、文件, 經(jīng)審批的施工組織設(shè)計(施工技術(shù)方案)進行施工。施工中發(fā)現(xiàn)問題應及時提出, 會同設(shè)計等拿出處理意見并及時處理,施工中不允許未經(jīng)同意擅自變更設(shè)計施工。施工中嚴格執(zhí)行施工程序,編制符合規(guī)范、工藝標準,具有可操作性的施工方案并做好交底。履行施工工序自檢、互檢、交接檢工作。每道工序未經(jīng)相關(guān)人員在驗收表上簽字,不得進行下道工序, 記錄好工作日志,防止監(jiān)督管理流于形式。在施工階段首先要嚴把材料、半成品及設(shè)備的質(zhì)量關(guān),從源頭抓起,控制好施工質(zhì)量。進場材料要有齊全的報驗合格資料(出廠合格證、檢測報告、復測報告等),并經(jīng)過監(jiān)理單位、建設(shè)單位驗收合格簽字后方可進場,從而將不合格材料進入工程的門路堵死;對于驗收不合格的材料要限期退場,禁止不合格的材料使用到工程中去。其次要嚴格控制分項、分部工程的質(zhì)量關(guān)。在施工階段中尤其要對關(guān)鍵工序、關(guān)鍵部位的質(zhì)量,重點檢查和控制。

        1、基礎(chǔ)施工階段的質(zhì)量控制

        在基礎(chǔ)工程施工時, 應依據(jù)圖紙設(shè)計做好防雷接地引下線的焊接;及時配合土建做好強、弱電專業(yè)的進戶電纜穿墻管及止水套管的預埋、預留工作。這一工作要求電氣專業(yè)必須趕在土建做外墻體防水處理之前完成, 避免電氣施工破壞防水層造成今后墻體滲漏;對需要設(shè)備基礎(chǔ)預埋件、預埋基礎(chǔ)螺栓及配電柜基礎(chǔ)型鋼等,電氣施工人員應提前做好準備, 待土建施工到位滿足預埋條件及時按圖埋入,并復查不得遺漏。電氣施工安裝中,管理人員只有努力提高自身的素質(zhì)和專業(yè)能力,才能把好質(zhì)量關(guān)。

        第4篇:電線電纜試驗報告范文

        關(guān)鍵詞:電氣工程;施工管理;配電工程;探討

        Abstract: the electrical engineering is contemporary architecture is an important part of the project, and to improve the overall construction engineering quality, it is necessary to improve the quality of electrical engineering. With the rapid development of electric equipment and kinds of increase, electrical installation technology is also more show complex. To make the electrical engineering construction to meet the expected purpose, must grasp the design, construction and operation management of the implementation course every step of the way. Combining with the following futong cast and real estate development Co., LTD, clear water of the sky garden and distribution engineering practice, the construction management of electrical engineering is discussed and the research, so that after the meaning of the experience.

        Keywords: electrical engineering; Construction management; Distribution of engineering; explore

        中圖分類號:F407.6文獻標識碼:A 文章編號:

        1. 工程概況

        東莞市富通鑄創(chuàng)房地產(chǎn)開發(fā)有限公司碧水長天花園配電工程:10/0.4kV變配電房位于小區(qū)負一層地下室,配變?nèi)萘浚?600kVA,單回10kV電源供電。安裝施耐德公司RM6型中壓開關(guān)柜共計11臺,安裝SCB10-1000kVA變壓器1臺,安裝SCB10-800kVA變壓器4臺,安裝SCB10-400kVA變壓器1臺,安裝GCK型低壓開關(guān)柜共55臺。小區(qū)配電房至各單元單體內(nèi)總配電箱采用電纜敷設(shè),總配電箱至各樓層住宅配電箱采用電線敷設(shè)。

        2. 建筑電氣施工管理存在的主要問題

        2.1工程施工人員素質(zhì)參差不齊

        目前,我國民用建筑電氣安裝工程的施工隊伍中,普遍存在施工質(zhì)量管理人員和安裝工人的綜合素質(zhì)不高,與現(xiàn)代電氣工程的要求存在著一定差距。他們雖有較豐富的現(xiàn)場施工經(jīng)驗,但缺乏專業(yè)理論知識。他們的特長是操作工藝,對專業(yè)技術(shù)性內(nèi)容和施工圖紙的理解存在不足。施工過程中,易發(fā)生暗配在混凝土中的配線保護管,混凝土保護層不足、拆模時外露、管子不暢通、穿越防火分區(qū)的保護措施不足、三根及二根以上導管在同一處交叉等現(xiàn)象,給后續(xù)的施工帶來不便,造成不必要的返工。

        2.2常用主要設(shè)備、材料存在問題

        當前,我國生產(chǎn)電氣設(shè)備及材料的生產(chǎn)廠家魚龍混雜,市面上存在大量不合格的電氣產(chǎn)品。例如:產(chǎn)品無合格證、3C認證、技術(shù)說明書和檢測試驗報告等文件資料;電線電纜的電阻率高、銅材雜質(zhì)含量過多、機械性能差、截面積小于標稱值、絕緣電阻小、抗腐蝕性能差、絕緣層與線芯嚴密性差、溫升系數(shù)大等;鋼管壁厚不足,鋼管內(nèi)表面毛刺過多,管徑不符合設(shè)計要求等。

        從以上兩點可以清楚的認識到,無論是安裝工人的素質(zhì)問題還是設(shè)備、材料的質(zhì)量問題,都嚴重地影響了電氣工程的安裝質(zhì)量及以后的安全運行。所以,現(xiàn)階段電氣施工管理的重點就在于人員及設(shè)備、材料的管理。

        3. 加強工程施工人員的質(zhì)量管理意識

        要保證和提高電氣工程的質(zhì)量,人是決定性因素。因此必須樹立“質(zhì)量第一,預防為主”的思想,以主人翁的態(tài)度保質(zhì)保量地完成電氣安裝工程任務。有些電氣質(zhì)量管理人員的選擇配合不嚴格,有的質(zhì)量管理人員資質(zhì)不符合質(zhì)量管理的基本要求,使質(zhì)量工作的開展受到一定的制約。對電氣質(zhì)量管理、監(jiān)督、檢測人員應實行執(zhí)業(yè)人員資格考核制度,按學歷、職稱、質(zhì)量管理工作年限和工作能力進行崗位安排,并經(jīng)過培訓考核后才能上崗。崗位工作要與其級別相結(jié)合,形成一種激進機制,這樣會促進質(zhì)量管理、檢測人員繼續(xù)學習深造,以提高管理工作的質(zhì)量。另一方面也可成立培訓中心,負責對電氣工程質(zhì)量管理人員、安裝工人的培訓,傳授規(guī)范中的相關(guān)質(zhì)量要求及新知識、新技術(shù)、新工藝、新材料,提高施工質(zhì)量管理人員的管理水平和安裝工人的綜合素質(zhì),把管理與服務有機結(jié)合起來,寓管理于服務之中,以管理帶服務,以服務促進管理,推動電氣工程質(zhì)量管理工作的規(guī)范化、程序化。

        4. 施工階段的質(zhì)量管理

        施工階段是工程項目實體形成的過程,也是形成產(chǎn)品質(zhì)量的最重要階段。電氣工程是通過一道道工序來完成。所以,電氣工程的質(zhì)量管理是從工序質(zhì)量到分項工程質(zhì)量、分部工程質(zhì)量的系統(tǒng)控制過程,也是一個由投入原材料開始,直到工程驗收完成為止的全過程、全方位的質(zhì)量管理系統(tǒng)過程。

        4.1主體施工階段的質(zhì)量控制

        確?;炷羶?nèi)管線預埋到位準確,縮短工期,使施工科學地進行。本階段常見工程質(zhì)量通病主要有防雷接地系統(tǒng)不符合要求、室外進戶管預埋不符合要求,必須在施工過程中注意消除。在預埋時,要根據(jù)工程特點,派專人負責與土建單位協(xié)調(diào),根據(jù)土建澆注混凝土的進度要求及流水作業(yè)的順序,逐層逐段按設(shè)計施工圖進行預留和預埋工作,按施工圖坐標位置要求土建標出結(jié)構(gòu)的標高線和水平軸線,按照設(shè)計坐標、標高位置進行施工,以利管道敷設(shè)到位。對需要預埋的鐵件、吊卡、木磚、吊桿基礎(chǔ)螺栓及配電柜基礎(chǔ)型鋼等預埋件。電氣施工人員應配合土建提前做好預備,土建施工到位及時埋入,不得遺漏?;A(chǔ)施工階段電氣工程專業(yè)應趕在土建做墻體防水處理之前完成,避免電氣施工破壞防水層造成墻體今后滲漏。均壓環(huán)、避雷帶、防雷引下線等焊接長度及質(zhì)量是否滿足規(guī)范及設(shè)計要求,是否漏焊要仔細檢查,特別是結(jié)構(gòu)轉(zhuǎn)換層,由于柱子主筋調(diào)整,防雷引下線容易錯焊、漏焊,必須認真檢查,確保工程質(zhì)量。裝修施工抹灰之前,電氣施工人員在內(nèi)墻上彈出的水平線和墻面線,將所有電氣工程中的預留孔洞、暗配管路按設(shè)計和規(guī)范要求核實一遍,符合要求后將箱盒穩(wěn)定好,然后掃通管路,穿好帶線,堵好管盒。

        4.2安裝階段的質(zhì)量管理

        施工前必須組織技術(shù)管理人員對電氣設(shè)計圖紙和相關(guān)技術(shù)文件,進行充分的消化吸收,分系統(tǒng)建立質(zhì)量控制點,并明確控制內(nèi)容、主控責任人,制訂作業(yè)指導書,給批準后實施。加強施工工藝質(zhì)量的控制,工藝流程對質(zhì)量的要求,工藝加工對施工操作技術(shù)的要求,做到施工工藝質(zhì)量控制標準化、規(guī)范化、制度化。注意施工細節(jié)的完善和控制,特別注意線管的彎曲半徑與線纜匹配、導線進入盒箱內(nèi)應有適當余量、線管穿越墻地面進導管內(nèi)的封堵、線管橋架穿越防火分區(qū)的防火封堵、線纜穿入穿出配電箱的封堵、線纜穿入穿出配電箱或線管時護線套的安裝、電纜標志牌的正確掛設(shè)等。及時檢驗工序活動效果的質(zhì)量,嚴格執(zhí)行“三檢”制,對質(zhì)量狀況進行綜合統(tǒng)計與分析,及時掌握質(zhì)量動態(tài)。一旦發(fā)現(xiàn)質(zhì)量問題,隨即研究處理,自始至終使工序活動效果的質(zhì)量滿足規(guī)范和標準的要求。實行質(zhì)量監(jiān)督和否決制度。嚴格按要求或施工規(guī)范操作,堅決行使質(zhì)量否決權(quán),使業(yè)主及施工單位在工程建設(shè)中獲得最大的管理效益。

        4.3綜合調(diào)試階段的質(zhì)量管理

        綜合調(diào)試是整個電氣安裝工程的最后階段,對整個工程能否正常啟用起到關(guān)鍵作用,是檢查施工質(zhì)量的重要環(huán)節(jié)。綜合調(diào)試涉及到業(yè)主、監(jiān)理單位、施工單位及設(shè)備供應商,由業(yè)主協(xié)調(diào)各方的工作、監(jiān)理單位進行監(jiān)督、施工單位制訂調(diào)試方案并實施、設(shè)備供應商提供技術(shù)支持。

        5. 電氣工程施工的安全管理

        5.1 要堅持“預防為主,安全第一”的方針,編制針對本工程的安全技術(shù)措施及安全組織措施,對施工人員進行安全技術(shù)交底,并設(shè)專職持證上崗的安全員。

        5.2 在員工中進行安全宣傳,提高員工的自我防護意識,貫徹落實《安全生產(chǎn)法》、《電業(yè)安全工作規(guī)程》、《建筑業(yè)安全衛(wèi)生公約》等安全法規(guī),遵守安全生產(chǎn)法律、法規(guī)和安全技術(shù)標準、規(guī)范,對員工進行安全教育培訓,提高員工的安全意識。在對員工進行教育培訓的基礎(chǔ)上,對易發(fā)生事故的分項工程進行安全檢查,發(fā)現(xiàn)問題及時糾正。

        5.3 強化電氣技術(shù)措施及要點,在使用電壓高于36V 的手電鉆時,要戴絕緣手套,穿絕緣鞋并檢查其是否有損壞;在施工中拆除的電線要及時進行處理,用絕緣帶包扎帶電的線頭;高空作業(yè)前要檢查安全帶的牢固程度,檢查扶梯有無防滑措施;登高作業(yè)時,不能隨意往下扔東西,要使用工具袋進行傳遞。

        5.4 建立技術(shù)交底制度,向?qū)I(yè)電工、各類用電人員介紹施工組織設(shè)計和安全用電技術(shù)措施的總體意圖、技術(shù)內(nèi)容和注意事項,并在技術(shù)交底文字資料上履行簽字手續(xù),注明交底日期。

        6. 結(jié)論

        為了提高建筑電氣工程施工質(zhì)量,應把“質(zhì)量第一、安全第一”放在首位,應根據(jù)工程的自身特點,必須把握好設(shè)計、施工及運行管理等實施過程的每一個環(huán)節(jié)。本文結(jié)合東莞市富通鑄創(chuàng)房地產(chǎn)開發(fā)有限公司碧水長天花園配電工程實際,對電氣工程的施工質(zhì)量管理進行了探討及并提出了管理措施,以便以后具有借鑒之意義。

        參考文獻:

        [1] 趙興威.淺談建筑電氣工程施工管理[J].沿海企業(yè)與科技,2010,02:99-100.

        第5篇:電線電纜試驗報告范文

        【關(guān)鍵詞】 游樂設(shè)施 電氣自動化 設(shè)備 可靠性

        2001年1月3日國家質(zhì)量技術(shù)監(jiān)督局局務會議審議通過并《游樂園管理規(guī)定》,游藝機和游樂設(shè)施應當符合《游藝機和游樂設(shè)施安全標準》和質(zhì)量技術(shù)監(jiān)督行政部門有關(guān)特種設(shè)備質(zhì)量監(jiān)督與安全監(jiān)察規(guī)定。因此,在各個行業(yè)電氣自動化程度不斷深入發(fā)展的今天,如何保證電氣自動化控制設(shè)備的可靠性是目前需要迫切解決的問題。

        1 電氣自動化控制設(shè)備可靠性的現(xiàn)狀

        據(jù)不完全統(tǒng)計,目前我國在用游樂設(shè)施已達2萬多臺(套),大中型游樂園200余家,每年約有4億人次以上參加游樂活動。游樂設(shè)施運行中一旦出現(xiàn)故障,輕者會造成游客懸??罩校卣邥苯油{其生命安全。目前國內(nèi)的游樂設(shè)施檢驗方法還不盡完善,受到設(shè)備規(guī)模、可拆卸性、檢驗時間等諸多限制。

        1.1 工作環(huán)境多樣,操作維護不當

        游樂設(shè)施工作環(huán)境是非常惡劣的。電氣自動化控制設(shè)備需要面對多種多樣的工作環(huán)境,以應對環(huán)境因素對電氣自動化控制設(shè)備的不利影響。這些不利的環(huán)境因素主要包括氣候因素、機械作用力因素與電磁干擾因素。

        (1)氣候因素,主要包括濕度、氣壓、溫度、大氣污染、煙霧等,這些不利的環(huán)境因素會嚴重影響(干擾)電氣自動化控制設(shè)備的性能、損壞設(shè)備結(jié)構(gòu)、運行運動靈活性以及溫升過高等,甚至導致設(shè)備完全毀壞,不能正常工作;

        (2)機械作用力因素,主要是指電氣自動化控制設(shè)備在不同運載工具中可能會受到的各種機械作用力,例如,沖擊、震蕩以及離心加速力等,這些機械作用會嚴重影響和損壞電氣自動化控制設(shè)備的元器件,或者改變其參數(shù),或者致使其嚴重變形和斷裂,或者導致設(shè)備金屬件出現(xiàn)疲勞破壞;

        (3)電磁干擾因素,該因素是非可見因素,但是對電氣自動化控制設(shè)備的不利影響不能小視,一般而言,電氣自動化控制設(shè)備的工作充斥著各種電磁波,這些電磁波會增大設(shè)備的輸出噪聲,導致其工作失穩(wěn),甚至影響設(shè)備安全。除此之外,人員因素的影響也非常重要。

        1.2 設(shè)備元器件質(zhì)量不合格

        游樂設(shè)施電氣系統(tǒng)的設(shè)計功能必須滿足該游樂設(shè)施的運行控制和安全保護的需要,并滿足當?shù)丨h(huán)境條件下正常使用的要求,因此對電氣自動化控制設(shè)備要求比較高。現(xiàn)在電氣自動化控制設(shè)備元器件的生產(chǎn)廠家繁多,并且良莠不齊。

        2 提高電氣自動化控制設(shè)備可靠性的重要意義

        游樂設(shè)施能給人們帶來刺激和歡樂,但同時也存在一定危險性,如果不嚴格管理,可能給人們帶來無法 彌補的傷害。為保護人民群眾生命安全,依據(jù)《特種設(shè)備安全監(jiān)察條例》(國務院令第373號),國家質(zhì)量監(jiān)督檢驗檢疫總局(以下簡稱國家質(zhì)檢總局)及各級質(zhì)量技術(shù)監(jiān)督局對大中型游樂設(shè)施實行安全監(jiān)察,定期檢驗。

        2.1 可靠性是衡量設(shè)備質(zhì)量的重要指標之一

        產(chǎn)品質(zhì)量就是使產(chǎn)品能夠?qū)崿F(xiàn)其價值、滿足明示要求的特征和特質(zhì)。概括其特性,主要包括:性能、可靠性、經(jīng)濟性和安全性。由此可見,可靠性在產(chǎn)品質(zhì)量中占有主導地位。只有可靠性高,發(fā)生故障的次數(shù)才會少,那么維修費用就少,相應的安全性也隨之提高。因此,產(chǎn)品的可靠性是產(chǎn)品質(zhì)量的核心,是生產(chǎn)廠家追求的目標。

        2.2 可靠性能夠增強設(shè)備的市場競爭力

        隨著國家經(jīng)濟的高速發(fā)展,用戶不僅要求產(chǎn)品性能好,更重要的是要求產(chǎn)品的可靠性水平高。只有那些具有高可靠性指標的產(chǎn)品,才能在日益激烈的競爭中得以取勝。隨著電氣自動化控制設(shè)備自動化程度、復雜度越來越高,可靠性技術(shù)已成為企業(yè)在競爭中獲取市場份額的有力工具。

        3 電氣自動化控制設(shè)備可靠性測試方法

        3.1 可靠性測試的主要方法

        根據(jù)國家電控配電設(shè)備質(zhì)量監(jiān)督檢驗中心提出的測試方法,目前常用的可靠性測試方法主要有試驗室測試方法、保證試驗方法、現(xiàn)場測試方法這三種。

        (1)試驗室測試方法,是利用一種可現(xiàn)試驗目的??氐?、規(guī)定的工作環(huán)境和條件來真實地、全方位地進行現(xiàn)場模擬測驗,它適用于大批量生產(chǎn)的產(chǎn)品。此方法的優(yōu)點試驗條件容易控制、試驗結(jié)果可以再現(xiàn)、實驗數(shù)據(jù)質(zhì)量高,缺點試驗花費很大,試驗條件限制性高,試品很多。

        (2)保證試驗方法,是在產(chǎn)品出廠前,在規(guī)定條件下對產(chǎn)品進行無故障的工作試驗,它適用于小規(guī)模生產(chǎn)、可靠性要求較高及設(shè)備構(gòu)造復雜的設(shè)備。此方法的優(yōu)點能測試出機器是隨機的、多種多樣的故障,缺點試驗跨度時間長,且電路復雜。

        (3)現(xiàn)場測試方法,是將設(shè)備置于真實的現(xiàn)場來進行可靠性測試, 一般有脫機測試、在線測試和停機測試,它適用于穩(wěn)定成熟的工藝條件、原件正規(guī)且高質(zhì)量的生產(chǎn)產(chǎn)品。此方法的優(yōu)點所需試品較少,試驗成本低,數(shù)據(jù)真實度較高,缺點測試環(huán)境不可控制,受外界影響較大,試驗再現(xiàn)困難。

        3.2 游樂設(shè)施可靠性測試方法的選擇

        如何選擇可靠性測試方法, 可以從試驗環(huán)境、場地、產(chǎn)品、測試程序、組織工作等幾個方面進行考慮推斷?,F(xiàn)在我司運行的大中型游樂設(shè)施中基本都是進口設(shè)施,因此在可靠性測試方面我司更偏重于試驗產(chǎn)品的選擇,及對定制游樂設(shè)施的要求,及首臺游樂設(shè)施的型式試驗。

        3.2.1 試驗產(chǎn)品的選擇

        試驗產(chǎn)品要具有典型性。從性質(zhì)上講,產(chǎn)品屬性有中小型設(shè)備和大型設(shè)備。從工作運行情況看,既有連續(xù)運行設(shè)備又有間斷運行設(shè)備。從工作運行情況上講,可分為連續(xù)運行設(shè)備和間斷運行設(shè)備。

        3.2.2 對定制設(shè)施的要求

        例如:首先要求游樂設(shè)施必須配置具有電氣安全保護功能(如過流、過壓、欠壓、缺相、短路。漏電、超速、低速、聯(lián)鎖等)的裝置,其裝置中的保護元件應與保護特性相匹配,并在明顯位置設(shè)置緊急控制按鈕和必要的聲光報警裝置。

        其次是規(guī)定電氣系統(tǒng)中配備的智能化控制設(shè)備、電力驅(qū)動裝置、電子元器件等技術(shù)性能(如容量、電壓等級,速度、溫度、防護等級,頻率、抗干擾性能等)和電線電纜的規(guī)格必須符合該游樂設(shè)施的正常安全使用要求;國家明令禁止的或淘汰的產(chǎn)品不得選用。

        3.2.3 首臺游樂設(shè)施的型式試驗

        中國特種設(shè)備檢測研究院對新引進的游樂設(shè)施進行型式試驗,為了保證測試的準確性和可信性, 在實際試驗中試驗人員要嚴格按程序進行試驗。具體來說,主要有:記錄各種性能指標、排除保障、數(shù)據(jù)采集、記錄保障情況、時間間隔的確定、試驗起始結(jié)束時間等,特檢院這個實驗是對游樂設(shè)施整體檢驗,需要設(shè)備無故障運行80個小時,以及滿載、偏載、空載等測試,這整個過程中對電氣設(shè)備的各個性能都得以測試。

        3.2.4 試驗的組織工作

        每一項工作都需要有一個高效嚴密的組織工作機構(gòu),該機構(gòu)應該由試驗人員、行業(yè)管理人員、科研管理人員共同組織,他們負責對各分散試驗場地的管理和組織工作,對試驗人員的選定、試驗工作的協(xié)調(diào)、對試驗數(shù)據(jù)的進行收集、對試驗報告的分析,最終對試驗結(jié)果的進行判定,與此同時還要把制造工程師、可靠性設(shè)計工程師以及現(xiàn)場工程師他們聯(lián)系在一起。只有對現(xiàn)場的測試進行全面管理,這樣才能得到好的結(jié)果。

        3.3 游樂設(shè)施現(xiàn)場可靠性測試方法

        進行現(xiàn)場可靠性主要步驟: 明確現(xiàn)場可靠性測試目的、確定現(xiàn)場可靠性試驗的條件、最后對可靠性數(shù)據(jù)進行統(tǒng)計分析。

        3.3.1 現(xiàn)場可靠性測試目的

        現(xiàn)場可靠性測試目的主要有:①為制定合理的可靠性考核指標提供依據(jù),通過收集現(xiàn)場可靠性數(shù)據(jù),進行可靠性評估;②得到可靠性數(shù)據(jù)指標,通過對收集現(xiàn)場的數(shù)據(jù)經(jīng)過數(shù)理統(tǒng)計分析;③為今后元器件的使用提出可靠性指標,通過收集設(shè)備上元器件的可靠性數(shù)據(jù);④確定出廠時設(shè)備進行的烤機時間,通過對設(shè)備的壽命特性進行考查;⑤為維修提供評估依據(jù),通過對現(xiàn)場的設(shè)備維修性數(shù)據(jù)進行收集。

        3.3.2 現(xiàn)場可靠性試驗的條件

        前提條件主要有:要求設(shè)備的工作條件符合產(chǎn)品的技術(shù)標準;要求產(chǎn)品有品質(zhì)保證;要求有成熟工藝條件;要求有正規(guī)的元器件;要求有完善的設(shè)備生產(chǎn)管理制度。為了使統(tǒng)計數(shù)字可靠,用戶使用的電控及自動化設(shè)備的數(shù)量最好多一些。

        3.3.3 可靠性數(shù)據(jù)統(tǒng)計分析

        按照電控設(shè)備可靠性指標體系的要求,對可靠性數(shù)據(jù)進行統(tǒng)計分析,最后不僅得到可靠性特征,還可以從中尋找一些規(guī)律。通過對以收集的數(shù)據(jù)進行統(tǒng)計計算,結(jié)構(gòu)表明,典型的或代表性的國產(chǎn)電控及自動化設(shè)備的平均無故障工作時間。

        4 結(jié)語

        綜上所述,保證電氣設(shè)備的可靠性是一個復雜的涉及廣泛知識領(lǐng)域的系統(tǒng)工程。游樂設(shè)施安全運營關(guān)鍵是經(jīng)營者規(guī)范管理,和游樂園(場)定期檢查督促。真正做到有章可循、違章必究,才能降低游樂設(shè)施的風險性。

        參考文獻:

        无码人妻一二三区久久免费_亚洲一区二区国产?变态?另类_国产精品一区免视频播放_日韩乱码人妻无码中文视频
      2. <input id="zdukh"></input>
      3. <b id="zdukh"><bdo id="zdukh"></bdo></b>
          <b id="zdukh"><bdo id="zdukh"></bdo></b>
        1. <i id="zdukh"><bdo id="zdukh"></bdo></i>

          <wbr id="zdukh"><table id="zdukh"></table></wbr>

          1. <input id="zdukh"></input>
            <wbr id="zdukh"><ins id="zdukh"></ins></wbr>
            <sub id="zdukh"></sub>
            易门县| 额尔古纳市| 繁峙县| 金湖县| 楚雄市| 高邑县| 丹寨县| 远安县| 铜陵市| 天峻县| 溧阳市| 柘荣县| 武强县| 苏尼特右旗| 铜陵市| 卢湾区| 彭泽县| 雷波县| 丰台区| 仙居县| 太保市| 扶绥县| 平昌县| 边坝县| 翼城县| 宁安市| 通渭县| 兴安盟| 收藏| 赤壁市| 麻城市| 措美县| 井研县| 凉城县| 越西县| 巧家县| 安多县| 东港市| 三都| 贵溪市| 莱芜市| http://444 http://444 http://444